    Position:Home > Products > Tower > HR900 Series[1~10KVA]

    HR900 Series

    ·Description

    HR900 series1-in/1-out 1KVA ~ 10KVAis a new generation of (parallel redundant N+X) double transformation and frequency online UPS, which designed by power star to meet with the requirements of Chinese power grid environment and the network system of the power. System control chip with 32 bit data bus microprocessor, which has great performance and accurately and quickly detect and control all working points of UPS, with rapid response to the change of external environment, ensuring the high reliability of the products; for China power grid environment of professional design makes the UPS input voltage, of which the frequency range is extremely wide; advanced times pressure type PFC technology makes the UPS input power factor close to 1; online double conversion structure design makes the UPS output frequency and voltage stabilizing, filtering noise, not affected by power fluctuation interference of sine wave power; when the power is cut or restored, there is no switching time for the UPS output; the digital control technology is used to realize the parallel expansion and parallel redundant function, and provide users with the power source planning flexibility and better security protection; intelligent battery management technology greatly prolongs the service life of the battery; LED+LCD display allows users to intuitively understand UPS running state and loading condition; Clients can use the PC RS232 interface through the UPS real-time understanding of work status, historical records and automatic switch machine; SNMP cards and related software can realize unattended and remote network monitoring and management, adapting to advanced network system using.

    ·Features

    ■Adopt advanced DSP digital control technology, which makes UPS performance stable and quality reliable;
    ■Adopt digital power factor correction technique (PFC), so that the input power factor is close to 1, reduce the power waste, completely eliminate UPS to electric power pollution, thus realizing the real green power;
    ■Achieve almost 90% of the full load operation efficiency, could reduce UPS power loss, and save expenditure of charge of electricity which is effective for you;
    ■Provide the best power for loading equipment by outputting low distortion sine wave power, either in AC mode or battery mode;
    ■The wide input voltage and frequency range, avoid grid voltage changes, frequently switch to battery power supply, and adapt to the harsh environment of the power region;
    ■The city electrical abnormalities (including electric power or the electric voltage is too high, too low, or frequency exceed the standard) or electricity is restored, the UPS output without switching time, meet the high standards and high demands of sophisticated equipments to the UPS power supply;
    ■Starting from the diagnosis functions, avoiding pitfalls and UPS may trigger failure risks;

    ■Comprehensive protection function, with the AC input, over and under-voltage protection, rectifier over and under-voltage protection, output, output under voltage protection, overload, short circuit protection, over temperature protection inverter multi function s protection in one, greatly guarantee the stability and reliability of the system;
    6KVA-10KVA can realize the N+X redundant functions, automatic load sharing, if one UPS fails, will automatically cut off the output, the load from the remaining UPS will provide power supply and parallel redundancy to improve the reliability of UPS system, of which the UPS is the mainstream technology in the field;
    ■The bypass function, when the UPS failure occurs, power to the load through bypass uninterruptedly, and provides a sound and light alarm;
    ■By the operation panel alarm silencing function button, can avoid unnecessary loud sound, when the battery voltage is low or the UPS exception occurs, the alarm can be automatically restored;
    ■The DC cold start function, unique DC (DC) boot, the public power is interrupted when the battery for start UPS directly, giving full play to the UPS emergency functions, making the use of which more convenient and reliable;

    ■The overload or inverter failure conditions, UPS will convert to bypass state, by the power supply; if the overload condition is removed, UPS will be automatically transferred back to the inverter power supply state;
    ■The intelligent unattended function, when the UPS in electric power or electric under-voltage or ultra high pressure and enable battery mode power supply, ultimately for the battery under-voltage automatic protection shutdown; when the utility power is restored, the UPS first detection voltage, frequency is within the normal range, when the electric voltage, frequency in the normal range, UPS since the start of the power to the load; when the electric voltage, frequency is not in the normal range, UPS is only starting charger to charge the battery, until the voltage, frequency recovered to within the normal range or charging of the battery voltage reaches a predetermined value UPS to start trend load power supply;
    1KVA-3KVA zero line reversal detection function, avoid UPS input power zero line plug;
    ■To prevent false triggering function, each key has a delay function, only the sustained one reaches a predetermined time value, the key will play a role of corresponding functions, in order to prevent the misuse of shutdown, shutdown key predetermined time value is set for the longest one;
    1KVA-3KVA with surge voltage protection function (TVSS), ensure the telephone, fax, Modem, network and other communications from UPS surge, the lightning disturbance (unique);
    ■With remote power function (EPO), when accidents happened, people can quickly turn off UPS;
    ■The battery protection function, effectively prevent the battery discharge / charging battery might cause permanent damages and short life expectancy, battery under-voltage warning function can inform the user relevant treatment is carried out, and by setting the regularly self-checking, early detection of battery failure, avoid loss;
    ■Intelligent battery management function (ABM) technology, effectively extending the service life of the battery, reduce the number of battery maintenance. The use of advanced automated conversion of constant current and constant voltage charging technology, the maximum activation cell, save the charging time, thereby prolonging the service life of the battery;

    ■In the normal city, no battery is needed to start the UPS, both to meet the user's demand of emergency rescue, and to be in maximum repair damage cell;
    ■The long-acting type in the city power under pressure or high pressure and enabling battery mode power supply, the built-in high current charger and battery connected in parallel to the UPS provides DC current, thus prolonging the standby time UPS, UPS in half, 1 times longer than that of standby time;
    ■The configuration manual repair bypass, as long as the UPS is to repair its mode, it can be in continuous supply for a load under the condition of on line repair;
    ■The selection of isolation transformer, the input and output of which are isolated, which provide the user with isolated protections;

    ■Can be paired with generator uses, use time more extended, and effectively ,remove the generator to generate power for the load side, and provide clean, safe, stable power supply;
    ■The centralized control panel can provide rich information (LED/LCD panel display panel optional), LED communication interface in a graphic display of UPS power supply, inverter, battery powered, bypass power supply, UPS fault, battery capacity, load capacity of working condition; LCD liquid crystal display interface to the user accurately display the current, voltage, UPS frequency, fault information, work environment, work conditions and load conditions, so that the various parameters of UPS stick out a mile display interface in the LCD, which can master the UPS power supply quality and changes of environment at any time;

    ■The adoption of advanced technology for anti electromagnetic interference, electromagnetic interference and radio frequency interference, of which is in line with international standards EN50091-2 and IEC61000-4 series standard design, and has very good electromagnetic compatibilities, with minimizing or even eliminating the equipments caused by electromagnetic interference;

    ■ UPS between PC and UPS through RS232 interface, multiple functions of monitoring, real-time understanding of the working state of UPS, historical records and automatic switch machine, simplify the network management, improve the system reliability;

    ■The configuration of the SNMP card and monitoring software, using TCP/IP, SNMP, HTTP, TFTP, through the WEB browser, to achieve in the Internet/ Intranet remote monitoring, real-time status query, information management, remote control, parameters settings, user managements, historical data query comprehensive monitoring and management functions, and can send short message or Email to users to alarm through mobile phones or system administrators, support for the operating systems: Windows 7, Unix, Linux etc.

    ·Technical Specifications
    Model
    HR910S
    HR910H
    HR920S
    HR920H
    HR930S
    HR930H
    Capacity
    1KVA/900W
    2KVA/1800W
    3KVA/2700W
    Input and output
    1-in/1-out
    Input
    Cold start
    support the battery cold start, the default frequency is 50HZ(settable)
    Input voltage
    50%~125%(220VAC/230VAC/240VAC)
    80%~125% at 100% rated load
    70%~125% at 85% rated load
    60%~125% at 75% rated load
    50%~125% at 60% rated load
    Voltage switching point
    Low voltage switching 110VAC

    Low voltage recovery 121VAC

    High voltage switching 288VAC
    High voltage recovery 281VAC
    Input currenton
    4.8A
    9.6A
    14.4A
    Input frequency
    40~70Hz
    Power factor
    ≥0.97
    Output
    Rated voltage
    220VAC
    Output waveform
    sine wave
    Power factor
    0.9
    Voltage regulation
    ±1%
    Dynamic response
    ≤5% (0% - 100% -0%)
    Dynamic recovery
    ≤10ms (0% - 100% -0%)
    Voltage distortion
    ≤1% THD, linear load
    ≤5.5% THD, nonlinear load
    ≤5% THD, nonlinear load
    ≤5% THD, nonlinear load
    Frequency adaptive
    settable
    Trace range
    ±5Hz acquiescent
    Trace velocity
    0.5~5Hz/s,2 Hz/s acquiescent
    Battery mode
    (50±0.1) Hz acquiescent
    Current
    4.3A
    8.6A
    13.5A
    Overload capacity
    (Online mode)
    105%~130%: 1m then switch to bypass
    150%: 30s then switch to bypass
    Overload capacity
    (battery mode)
    105%~130%:maintain 10s then shutdown
    150%:maintain 5s then shutdown
    Overload capacity
    (bypass mode)
    <130%: normal
    130%~150%:1m then shutdown
    150%~180%:5s then shutdown
    Load crest factor
    3:1(Max)
    System
    Switching time
    0ms (main switch to battery)
    2ms(inverter switch to bypass)
    EMI/EMC
    IEC/EN 62040-2:2006 C3
    EMS
    IEC/EN 61000-4-2:2009 B (ESD)
    IEC/EN 61000-4-3:2006 +A1:2008 +A2:2010 A (RS)
    IEC/EN 61000-4-4:2004+A1:2010 B(EFT)
    IEC/EN 61000-4-5:2006 B(Surge)
    IEC/EN 61000-4-6:2009 A(RF)
    IEC/EN 61000-4-8:2010 A(Magnetic Field)
    IEC/EN 61000-4-11:2004 A(VD)
    IEC/EN 61000-2-2:2002 A(LF)
    Efficiency
    Main mode with
    batteries charged
    when 100% rated load, it is 86%
    when 50% rated load, it is 87%
    when 100% rated load, it is 88%
    when 50% rated load, it is 91%
    when 100% rated load, it is 88%
    when 50% rated load, it is 90%
    ECO mode
    94%
    97%
    97%
    Battery mode
    when 100% rated load, it is 83%
    when 50% rated load, it is 84%
    when 100% rated load, it is 87%
    when 50% rated load, it is 88%
    when 100% rated load, it is 87%
    when 50% rated load, it is 89%
    Noise
    (1m far away)
    when <60% rated load, it is <45dB
    when >60% rated load, it is <50dB
    when <60% rated load, it is <50dB
    when >60% rated load, it is <55dB
    when <60% rated load, it is <50dB
    when >60% rated load, it is <55dB
    Battery
    Type
    maintenance-free lead-acid batteries
    Model
    12VDC/7Ah
    depending on the external battery
    12VDC/7Ah
    depending on the external battery
    12VDC/7Ah
    depending on the external battery
    Quantity
    3
    6
    8
    Direct voltage
    36VDC
    72VDC
    96VDC
    Backup time
    80%load
    6m
    depending on the external battery
    80%load
    6m
    depending on the external battery
    80%load
    5.5m
    depending on the external battery
    Low-voltage battery
    33VDC~35VDC,changed by load factor
    66VDC~70VDC,changed by load factor
    88VDC~94VDC,changed by load factor
    Charger
    Charging voltage
    floating charge:41VDC/ equalized charging:42VDC
    floating charge:82VDC/ equalized charging:84VDC
    floating charge:109VDC/ equalized charging:112VDC
    Maximum charging current
    1A
    4A/8A
    1A
    4A/8A
    1A
    4A/8A
    Charging time
    8h up to 90%
    depending on the external battery
    8h up to 90%
    depending on the external battery
    8h up to 90%
    depending on the external battery
    Leakage current
    <1mA
    Display and alarm
    Display
    LED+LCD
    Battery discharge
    sounds every 2m
    Low-voltage battery
    sounds every 6s
    Overload
    persistent sound
    Abnormal input voltages (including phase sequence reversed, unearthed)
    sounds every 2m
    Alarm
    sounds every 6s
    Fault
    persistent sounding
    Interface
    RS232
    support background software through the standard cable
    SNMP(option)
    monitoring machine through the network monitoring machine
    EPO
    emergency shutdown
    Input
    IEC C14
    14.4A
    Output
    6*IEC C13
    14.4A
    Option
    IC card
    pluggable DB9 dry contact
    USB
    USB interface of type B
    SNMP
    pluggable
    Environment
    Temperature
    0~40℃
    Humidity
    0%~95%
    Altitude
    <1500m
    Physical characteristic
    Size(mm)
    (W*D*H)
    440*430*86
    (2U)
    440*430*86
    (2U)
    440*480*173
    (4U)
    440*480*86
    (2U)
    440*480*173
    (4U)
    440*480*86
    (2U)
    Packing size (mm)
    (W*D*H)
    580*565*250
    580*565*250
    580*660*335
    580*615*250
    580*660*335
    580*615*250
    Weight (kg))
    12
    6
    21
    10.5
    25.6
    11.5
    Gross weight (KG)
    13
    7
    22
    12
    27
    13
    Colour
    Black



    Model

    HR960H

    HR9010H

    Capacity

    6KVA/5400W

    10KVA/9000W

    Input and output

    1-in/1-out

    Input

    Cold start

    support the battery cold start, the default frequency is 50HZ(settable)

    Input voltage

    50%125%(220VAC/230VAC/240VAC)

    80%125% at 100% rated load

    70%125% at 85% rated load

    60%125% at 75% rated load

    50%125% at 60% rated load

    Voltage switching point

    Low voltage switching 110VAC/115VAC/120VAC

    Low voltage recovery 116VAC/122VAC/127VAC

    High voltage switching 275VAC/288VAC/300VAC

    High voltage recovery 268VAC/279VAC/291VAC

    Input currenton

    All surpot

    Input frequency

    4070Hz

    Power factor

    ≥0.99

    Output

    Rated voltage

    220/230/240VAC

    Output waveform

    sine wave

    Voltage regulation

    ±1%

    Dynamic response

    ≤5% (50% - 100% -50%)

    Dynamic recovery

    ≤15ms (0% - 100% -0%)

    Voltage distortion

    ≤1% THD,linear load

    ≤5% THD,nonlinear load

    Frequency adaptive

    settable

    Trace range

    ±3Hz acquiescent

    Trace velocity

    0.55Hz/s,2 Hz/s acquiescent

    Battery mode

    (50±0.05)Hz acquiescent

    Current

    27A

    45A

    Overload capacity

    (Online mode)

    110%: 10m then switch to bypass

    130%: 1m then switch to bypass

    150%:30s then switch to bypass,1m then shutdown

    Overload capacity

    (bypass mode)

    <110%: 10m then shutdown

    >115%:10s then shutdown

    Load crest factor

    3:1Max

    Power factor

    0.9

    System

    Switching time

    Main road cut battery 0ms, cut inverter bypass 0ms

    Repair bypass

    Standard

    EMI/EMC

    IEC/EN 62040-2:2006 C3

    EMS

    IEC/EN 61000-4-2:2009 B (ESD)

    IEC/EN 61000-4-3:2006 +A1:2008 +A2:2010 A (RS)

    IEC/EN 61000-4-4:2004+A1:2010 B(EFT)

    IEC/EN 61000-4-5:2006 B(Surge)

    IEC/EN 61000-4-6:2009 A(RF)

    IEC/EN 61000-4-8:2010 A(Magnetic Field)

    IEC/EN 61000-4-11:2004 A(VD)

    IEC/EN 61000-2-2:2002 A(LF)

    Efficiency

    Main mode

    92%

    ECO mode

    97%

    Battery mode

    91%

    Noise

    (1m far away)

    when <70% rated load, it is <48dB

    when >70% rated load, it is <58dB

    when <70% rated load, it is <48dB

    when >70% rated load, it is <60dB

    Battery

    Type

    maintenance-free lead-acid batteries

    Number

    1x16x12V

    Backup time

    depending on the external battery

    Low-voltage battery

    (176±3)VDC

    Charger

    Charging voltage

    (220±1%)VDC

    Maximum charging current

    5A

    Charging time

    depending on the external battery

    Leakage current

    <2mA

    Display and alarm

    Display

    LED+LCD

    Battery discharge

    sounds every 1s

    Fault

    persistent sounding

    Interface

    EPO

    emergency shutdown

    RS232

    support background software through the standard cable

    USB(option)

    support background software through the standard cable

    SNMP(option)

    monitoring machine through the network monitoring machine

    Input

    IEC C14

    IEC C20

    Output

    6*IEC C13

    6*IEC C13+1*IEC C19

    Option

    ECO

    Economic model

    Dry contact

    pluggable

    parallel operation

    3

    battery pack

    16 battery box

    USB

    USB interface of type B

    SNMP

    pluggable

    Environment

    Temperature

    040

    Storage temperature

    070

    Humidity

    0%95%

    Altitude

    In 1000M

    Standard

    Safety standard

    EN62040-1

    EMC

    EN62040-2EN61000-4-2EN61000-4-3EN61000-4-4EN61000-4-5EN61000-4-6

    Produce

    YD/T1095-2008

    Physical characteristic

    Size(mm)

    (W*D*H)

    438*130*680

    Weight(kg)

    21

    23

    Colour

    Black

    Products shall be subject to any changes without additional notices. The pictures are for reference only. Please adhere to the original products in case of any mistake!
    
  • About us
    About Powerstar
    Organizational Structure
    Values
    Qualification Honors
    Development Process
    Enterprice VI
    Chairman Message
  • E-commerce
    Local Agent
    Join In Agency
    Online Business
    Product Quotation
  • HR
    Talent Philosophy
    Education Training
    Recruitment Informat
    Job Application
  • Other information
    Links
    Site Map
    Legal Notices
    Privacy Statement
    Dalian OA login
    Beijing OA login
  • Contact us
    Domestic Business Platform
    R & D Base
    International Business Platform
    Region Branches
    Enterprise E-mail